Skip to main content

Identifying the LUN details on AIX with Script.

 


find out the lun details on AIX server use the below commands and scripts.

[root@ai1028:/home/root]# lsdev | grep hdisk
hdisk0 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk1 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk2 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk3 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk4 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk5 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk6 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk7 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk8 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk9 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk10 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)
hdisk11 Available 04-T1-01 XP MPIO Disk P9500 (Fibre)

i=12 means, 12 hdisks are there on the server

[root@ai1028:/home/root]# i=0;while((i<=12));do lscfg -vpl hdisk$i |grep -i hdisk;((i=$i+1));done
hdisk0 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-LB000000000000 XP MPIO Disk P9500 (Fibre)
hdisk1 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L0 XP MPIO Disk P9500 (Fibre)
hdisk2 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L1000000000000 XP MPIO Disk P9500 (Fibre)
hdisk3 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L2000000000000 XP MPIO Disk P9500 (Fibre)
hdisk4 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L3000000000000 XP MPIO Disk P9500 (Fibre)
hdisk5 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L4000000000000 XP MPIO Disk P9500 (Fibre)
hdisk6 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L5000000000000 XP MPIO Disk P9500 (Fibre)
hdisk7 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L6000000000000 XP MPIO Disk P9500 (Fibre)
hdisk8 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L7000000000000 XP MPIO Disk P9500 (Fibre)
hdisk9 U8408.E8D.107031T-V8-C604-T1-W50060E80166F8D32-L8000000000000 XP MPIO Disk P9500 (Fibre)

[root@ai1028:/home/root]# lsdev -Cc adapter |grep -i Fibre
fcs0 Available 04-T1 Virtual Fibre Channel Client Adapter
fcs1 Available 05-T1 Virtual Fibre Channel Client Adapter
fcs2 Available 04-T1 Virtual Fibre Channel Client Adapter
fcs3 Available 05-T1 Virtual Fibre Channel Client Adapter
fcs4 Available 04-T1 Virtual Fibre Channel Client Adapter
fcs5 Available 04-T1 Virtual Fibre Channel Client Adapter

i=5 means, 5 fcs adapters are there.

[root@test:/home/root]# i=0;while((iwwn on AIX
Network Address………….C0507606A6C5003A
Network Address………….C0507606A6C5003C
Network Address………….C0507606A6C5003E
Network Address………….C0507606A6C50040
Network Address………….C0507606A6C50056
Network Address………….C0507606A6C50058

[test]#i=0;while((i LUN ID on AIX 5.3

value = “1F0C50 16F8D012006OPEN-V02HPfcp”
value = “1F0C50 16F8D003F06OPEN-V02HPfcp”
value = “1F0C50 16F8D004006OPEN-V02HPfcp”
value = “1F0C50 16F8D004106OPEN-V02HPfcp”
value = “1F0C50 16F8D004206OPEN-V02HPfcp”
value = “1F0C50 16F8D004306OPEN-V02HPfcp”
value = “1F0C50 16F8D004406OPEN-V02HPfcp”
value = “1F0C50 16F8D004506OPEN-V02HPfcp”
value = “1F0C50 16F8D004606OPEN-V02HPfcp”
value = “1F0C50 16F8D004706OPEN-V02HPfcp”
value = “1F0C50 16F8D004806OPEN-V02HPfcp”
value = “1F0C50 16F8D004906OPEN-V02HPfcp”
==============================
LUN ID example
0120
03F0
0040
0041
================================
[test]#i=0;while((isize of the disk(LUN)
1200
03F0
0400
0410
0420
0430
0440
0450
0460
0470
0480
0490


Comments

Popular posts from this blog

HP SMART ARRAY CLI COMMANDS

Show configuration : /opt/hp/hpssacli/bin/hpssacli ctrl all show config Controller status /opt/hp/hpssacli/bin/hpssacli ctrl all show status Show detailed controller information for all controllers /opt/hp/hpssacli/bin/hpssacli ctrl all show detail Show detailed controller information for controller in slot 0 /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail Rescan for New Devices /opt/hp/hpssacli/bin/hpssacli rescan Physical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status Show detailed physical disk information /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail Logical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status View Detailed Logical Drive Status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show Create New RAID 0 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 Create New RAID 1 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld dri...

Monthly Mksys OS backup AIX

Step-1 Estimate Backup: ================================================================= df -tk `lsvgfs rootvg` | awk ‘{total+=$3}\ END {printf “Estimated mksysb size: %d bytes, %.2f GB\n”, total*1024, total/1024/1024}’ It will give you the estimated time of backup, Step-2 Backup Command: backupios -file /home/padmin/28August2013_TESTVIOI_mksysb ===============> VIO Backup Command mksysb -e -i -X /mksysb/10Nov2013_server-1_mksysb============================>AIX server Backup command Step-3 ================= Pre -checks: => check NFS FS size(Backup file) and root vg FS sizes . Note : if any FS Full Zip old logs => To check performance of the server => To check root VG FS => To check /etc/exclude ========================== Step-4 ================================ server-1 mksysb -e -i -X /mksysb/02March2014_server-1_mksysb server-2 mksysb -e -i -X /mksysb/02March2014_sever-2_mksysb Post checkups: ==> check the process running o...

HP proliant SERVER hardware commands

to check the failed disk, adapter, any physical component on hp prolient server use the below important command. # hpacucli controller all show config———-to See the failed disk in HP proliant server  Smart Array P410i in Slot 0 (Embedded) (sn: 500143802590F6C0) logicaldrive 1 (558.9 GB, RAID 1, Interim Recovery Mode) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, Failed)====>indicating the faild drive SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143802590F6CF) [root@TEST:/root]# hpacucli ctrl slot=0 show Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 500143802590F6C0 Cache Serial Number: PBCDH0CRH1Z6R3 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: C Firmware Version: 6.60 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Autom...