Skip to main content

Monthly Mksys OS backup AIX

Step-1
Estimate Backup:
=================================================================
df -tk `lsvgfs rootvg` | awk ‘{total+=$3}\
END {printf “Estimated mksysb size: %d bytes, %.2f GB\n”, total*1024, total/1024/1024}’
It will give you the estimated time of backup,
Step-2
Backup Command:
backupios -file /home/padmin/28August2013_TESTVIOI_mksysb ===============> VIO Backup Command
mksysb -e -i -X /mksysb/10Nov2013_server-1_mksysb============================>AIX server Backup command
Step-3
=================
Pre -checks:
=> check NFS FS size(Backup file) and root vg FS sizes . Note : if any FS Full Zip old logs
=> To check performance of the server
=> To check root VG FS
=> To check /etc/exclude
==========================
Step-4
================================
server-1
mksysb -e -i -X /mksysb/02March2014_server-1_mksysb
server-2
mksysb -e -i -X /mksysb/02March2014_sever-2_mksysb
Post checkups:
==> check the process running or not ps -ef |grep -i mksysb
===> check Root VG FS sizes
===> check the backup FS size .
==> to check the backup is sucesfull are not ( lsmksysb -l backup file name )
VIO server Backup:
================================================================================================
TESTVIO1:
—————————-
mksysb -e -i -X /tmp/02March2014_TESTVIO1_mksysb ================> to take mksysb backup taken file
lsmksysb -l -f 12Feb2014_TESTVIO1_mksysb =================> to check mksysb sucess or not
Mksysb error:
=====================
# mksysb -e -i -X /mksysb/09Feb2014_server-1_mksysb
0503-903 chedition: Edition can not be determined.
A signature file was not found in the /usr/lpp/bos directory.
Creating information file (/image.data) for rootvg.
Creating list of files to back up.
.
Backing up 124971 files…………………………
30645 of 124971 files (24%)…………………………
42122 of 124971 files (33%)…………………………
42751 of 124971 files (34%)……………………backup: 0511-089 Cannot open ./var/tmp/netcd.lock: Cannot open or remove a file containing a running program.
……
50590 of 124971 files (40%)…………………………
93372 of 124971 files (74%)……………..
0512-003 mksysb may not have been able to archive some files.
The messages displayed on the Standard Error contained additional
information.
==================================================================================
By: Bibhut Bhusan

Comments

Popular posts from this blog

HP SMART ARRAY CLI COMMANDS

Show configuration : /opt/hp/hpssacli/bin/hpssacli ctrl all show config Controller status /opt/hp/hpssacli/bin/hpssacli ctrl all show status Show detailed controller information for all controllers /opt/hp/hpssacli/bin/hpssacli ctrl all show detail Show detailed controller information for controller in slot 0 /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail Rescan for New Devices /opt/hp/hpssacli/bin/hpssacli rescan Physical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status Show detailed physical disk information /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail Logical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status View Detailed Logical Drive Status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show Create New RAID 0 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 Create New RAID 1 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld dri...

HP proliant SERVER hardware commands

to check the failed disk, adapter, any physical component on hp prolient server use the below important command. # hpacucli controller all show config———-to See the failed disk in HP proliant server  Smart Array P410i in Slot 0 (Embedded) (sn: 500143802590F6C0) logicaldrive 1 (558.9 GB, RAID 1, Interim Recovery Mode) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, Failed)====>indicating the faild drive SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143802590F6CF) [root@TEST:/root]# hpacucli ctrl slot=0 show Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 500143802590F6C0 Cache Serial Number: PBCDH0CRH1Z6R3 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: C Firmware Version: 6.60 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Autom...