Skip to main content

HP SMART ARRAY CLI COMMANDS

Show configuration:
/opt/hp/hpssacli/bin/hpssacli ctrl all show config
Controller status
/opt/hp/hpssacli/bin/hpssacli ctrl all show status
Show detailed controller information for all controllers
/opt/hp/hpssacli/bin/hpssacli ctrl all show detail
Show detailed controller information for controller in slot 0
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail
Rescan for New Devices
/opt/hp/hpssacli/bin/hpssacli rescan
Physical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status
Show detailed physical disk information
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail
Logical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status
View Detailed Logical Drive Status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show
Create New RAID 0 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
Create New RAID 1 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
Create New RAID 5 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
Delete Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete
Add New Physical Drive to Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
Add Spare Disks
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
Enable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable
Disable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable
Erase Physical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase
Turn on Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on
Turn off Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off
Modify smart array cache read and write ratio(cacheratio=readratio/writeratio)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0
Enable smart array write cache when no battery is present (No-Battery Write Cache option)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable
Disable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
Enable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
Enable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
Disable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable

Running ADU report without hpacucli
cd /opt/hp/hpssaducli/bin
[test]:/opt/hp/hpssaducli/bin # ls
hpssaducli hpssaduesxi upgrade.txt
[test]:/opt/hp/hpssaducli/bin # ./hpssaducli -f /tmp/adu-report.zip
HP Smart Storage Diagnostics 1.60.17.0


By:Bibhuti Bhusan

Comments

Popular posts from this blog

Monthly Mksys OS backup AIX

Step-1 Estimate Backup: ================================================================= df -tk `lsvgfs rootvg` | awk ‘{total+=$3}\ END {printf “Estimated mksysb size: %d bytes, %.2f GB\n”, total*1024, total/1024/1024}’ It will give you the estimated time of backup, Step-2 Backup Command: backupios -file /home/padmin/28August2013_TESTVIOI_mksysb ===============> VIO Backup Command mksysb -e -i -X /mksysb/10Nov2013_server-1_mksysb============================>AIX server Backup command Step-3 ================= Pre -checks: => check NFS FS size(Backup file) and root vg FS sizes . Note : if any FS Full Zip old logs => To check performance of the server => To check root VG FS => To check /etc/exclude ========================== Step-4 ================================ server-1 mksysb -e -i -X /mksysb/02March2014_server-1_mksysb server-2 mksysb -e -i -X /mksysb/02March2014_sever-2_mksysb Post checkups: ==> check the process running o...

HP proliant SERVER hardware commands

to check the failed disk, adapter, any physical component on hp prolient server use the below important command. # hpacucli controller all show config———-to See the failed disk in HP proliant server  Smart Array P410i in Slot 0 (Embedded) (sn: 500143802590F6C0) logicaldrive 1 (558.9 GB, RAID 1, Interim Recovery Mode) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, Failed)====>indicating the faild drive SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143802590F6CF) [root@TEST:/root]# hpacucli ctrl slot=0 show Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 500143802590F6C0 Cache Serial Number: PBCDH0CRH1Z6R3 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: C Firmware Version: 6.60 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Autom...