Skip to main content

Ifenslave Uses in Linux



ifenslave – Attach and detach slave network devices to a bonding device.
Description
ifenslave is a tool to attach and detach slave network devices to a bonding device. A bonding device will act like a normal Ethernet network device to the kernel, but will send out the packets via the slave devices using a simple round-robin scheduler. This allows for simple load-balancing, identical to “channel bonding” or “trunking” techniques used in switches.
The kernel must have support for bonding devices for ifenslave to be useful.
Options
-a, –all-interfaces
Show information about all interfaces.
-c, –change-active
Change active slave.
-d, –detach
Removes slave interfaces from the bonding device.
-f
Force actions to be taken if one of the specified interfaces appears not to belong to an Ethernet device.
-h
Display a help message and exit.
-u
Show usage information and exit.
-v, –verbose
Print warning and debug messages.
-V, –version
Show version information and exit.
If not options are given, the default action will be to enslave interfaces.
Example
The following example shows how to setup a bonding device and enslave two real Ethernet devices to it:
# modprobe bonding
# ifconfig bond0 192.168.0.1 netmask 255.255.0.0
# ifenslave bond0 eth0 eth1
By Bibhuti Bhusan

Comments

Popular posts from this blog

HP SMART ARRAY CLI COMMANDS

Show configuration : /opt/hp/hpssacli/bin/hpssacli ctrl all show config Controller status /opt/hp/hpssacli/bin/hpssacli ctrl all show status Show detailed controller information for all controllers /opt/hp/hpssacli/bin/hpssacli ctrl all show detail Show detailed controller information for controller in slot 0 /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail Rescan for New Devices /opt/hp/hpssacli/bin/hpssacli rescan Physical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status Show detailed physical disk information /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail Logical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status View Detailed Logical Drive Status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show Create New RAID 0 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 Create New RAID 1 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld dri...

Monthly Mksys OS backup AIX

Step-1 Estimate Backup: ================================================================= df -tk `lsvgfs rootvg` | awk ‘{total+=$3}\ END {printf “Estimated mksysb size: %d bytes, %.2f GB\n”, total*1024, total/1024/1024}’ It will give you the estimated time of backup, Step-2 Backup Command: backupios -file /home/padmin/28August2013_TESTVIOI_mksysb ===============> VIO Backup Command mksysb -e -i -X /mksysb/10Nov2013_server-1_mksysb============================>AIX server Backup command Step-3 ================= Pre -checks: => check NFS FS size(Backup file) and root vg FS sizes . Note : if any FS Full Zip old logs => To check performance of the server => To check root VG FS => To check /etc/exclude ========================== Step-4 ================================ server-1 mksysb -e -i -X /mksysb/02March2014_server-1_mksysb server-2 mksysb -e -i -X /mksysb/02March2014_sever-2_mksysb Post checkups: ==> check the process running o...

HP proliant SERVER hardware commands

to check the failed disk, adapter, any physical component on hp prolient server use the below important command. # hpacucli controller all show config———-to See the failed disk in HP proliant server  Smart Array P410i in Slot 0 (Embedded) (sn: 500143802590F6C0) logicaldrive 1 (558.9 GB, RAID 1, Interim Recovery Mode) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, Failed)====>indicating the faild drive SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143802590F6CF) [root@TEST:/root]# hpacucli ctrl slot=0 show Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 500143802590F6C0 Cache Serial Number: PBCDH0CRH1Z6R3 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: C Firmware Version: 6.60 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Autom...