Failed Disk Status on HP-proliant servers



#hpacucli controller all show config———->to See the failed disk in HP proliant server
Smart Array P410i in Slot 0 (Embedded) (sn: 500143802590F6C0)
logicaldrive 1 (558.9 GB, RAID 1, Interim Recovery Mode)
array A (SAS, Unused Space: 0 MB)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, Failed)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143802590F6CF)
[root@TEST:/root]# hpacucli ctrl slot=0 show
Smart Array P410i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 500143802590F6C0
Cache Serial Number: PBCDH0CRH1Z6R3
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: C
Firmware Version: 6.60
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 400 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True


By: Bibhuti Bhusan

Comments

Popular posts from this blog

HP SMART ARRAY CLI COMMANDS

Show configuration : /opt/hp/hpssacli/bin/hpssacli ctrl all show config Controller status /opt/hp/hpssacli/bin/hpssacli ctrl all show status Show detailed controller information for all controllers /opt/hp/hpssacli/bin/hpssacli ctrl all show detail Show detailed controller information for controller in slot 0 /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail Rescan for New Devices /opt/hp/hpssacli/bin/hpssacli rescan Physical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status Show detailed physical disk information /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail Logical disk status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status View Detailed Logical Drive Status /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show Create New RAID 0 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 Create New RAID 1 Logical Drive /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld dri...

Monthly Mksys OS backup AIX

Step-1 Estimate Backup: ================================================================= df -tk `lsvgfs rootvg` | awk ‘{total+=$3}\ END {printf “Estimated mksysb size: %d bytes, %.2f GB\n”, total*1024, total/1024/1024}’ It will give you the estimated time of backup, Step-2 Backup Command: backupios -file /home/padmin/28August2013_TESTVIOI_mksysb ===============> VIO Backup Command mksysb -e -i -X /mksysb/10Nov2013_server-1_mksysb============================>AIX server Backup command Step-3 ================= Pre -checks: => check NFS FS size(Backup file) and root vg FS sizes . Note : if any FS Full Zip old logs => To check performance of the server => To check root VG FS => To check /etc/exclude ========================== Step-4 ================================ server-1 mksysb -e -i -X /mksysb/02March2014_server-1_mksysb server-2 mksysb -e -i -X /mksysb/02March2014_sever-2_mksysb Post checkups: ==> check the process running o...

HP proliant SERVER hardware commands

to check the failed disk, adapter, any physical component on hp prolient server use the below important command. # hpacucli controller all show config———-to See the failed disk in HP proliant server  Smart Array P410i in Slot 0 (Embedded) (sn: 500143802590F6C0) logicaldrive 1 (558.9 GB, RAID 1, Interim Recovery Mode) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, Failed)====>indicating the faild drive SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143802590F6CF) [root@TEST:/root]# hpacucli ctrl slot=0 show Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 500143802590F6C0 Cache Serial Number: PBCDH0CRH1Z6R3 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: C Firmware Version: 6.60 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Autom...